This is an example of a study were where the sponsor collected events associated with the operation of the electronic cigarette device. Events not specifically associated with the device should not be represented in this domain.  

Xformpusher
OrderCDASHIG VariableQuestion TextPromptData TypeCRF Completion InstructionsSDTMIG TargetSDTM Variable MappingControlled Terminology Codelist NamePermissible ValuesPre-populated ValueQuery DisplayList StyleHidden
1SPTOBIDWhat was the tobacco product identifier? Tobacco Product Identifier textIndicate
the tobacco product
the  device that  was
involved in
associated with the
incident
event. SPTOBID


VAPE-Z01
radio
6PITERM

What was the event associated with this

tobacco product

device?

 

Tobacco Product
EventtextRecord a description of the event that occurred.PITERM






7PISTDATWhat was the start date when the event first occurred or was identified?Start DatetextRecord the date that the event first occurred or was noted using this format (DD-MON-YYYY).PISTDTC






10PIEPATTHow frequently did the event occur?Event FrequencytextRecord how often the event occurred.PIPATT

Single Event; Intermittent; Continuous

radio
11PIACNDEVWhat action was taken with the
study
device?Action Taken With DevicetextRecord what action was taken with the
tobacco product
device as a result of the event.PIACNDEV
(DEACNDEV)

No Change;

Tobacco Product

Device Replaced;

 

Battery Replaced



radio
12PIAENO(n)What was the identifier for the primary adverse event(s) associated with or related to this device event?Related Adverse Event IDtextRecord the ID of the primary AE associated with event, if any.N/AASSOCIATE WITH RELATED RECORD VIA RELREC





The associated SDTM datasets for the data collected above are provided below. The Tobacco Product Identifier (TO) domain is a study reference dataset that provides a mechanism for uniquely identifying a tobacco product. Only one product was of interest in the study.  Note this identifier also describes any device use by the subject to deliver the tobacco.   

...

Sponsor may use standardized or dictionary-derived text for the description of an product a device event/problem. CDISC does not provided provide information on the what standardized or dictionary-derived text should be used. 

...

Dataset wrap
NamePI
Dataset2

Row

STUDYID

DOMAIN

USUBJID

SPTOBID

PISEQ

PILNKID

PITERM

PIDECOD

PIMODIFY

PIACT

PIACNDEV

PISTDTC


PIIMDRCD

PIIMDRL2

PIIMDRL1

1

TB005

PI

2029

VAPE-Z01

1


Broken Heater

Mechanical Problem

Mechanical Problem

Device Replaced

2009-12-28


A05

Mechanical Problem

Mechanical Problem

2

TB005

PI

1059

VAPE-Z01

1


Won’t charge

Charging Problem

Charging Problem

Battery Replaced

2009-01-05


A0706

Charging Problem

Electrical /Electronic Property Problem

3

TB005

PI

3067

VAPE-Z01

1

1

Battery Malfunction

Battery Problem

Battery Problem

Battery Replaced

2009-01-05


A0705

Battery Problem

Electrical /Electronic Property Problem

Nsvmeta
DomainPI
VariableLabelTypeRoleOrigin
PIIMDRCDIMDR Code CharNon-standard Variable Qualifier of DEDECOD  Assigned
PIIMDRL2IMDR Level 2CharNon-standard Variable Qualifier of DEDECOD Assigned
PIIMDRL1IMDR Level 1CharNon-standard Variable Qualifier of DEDECOD Assigned

...

Subject 3067 had an AE associated with the battery problem. This was reported in the AE dataset. Not all variables are shown for brevity.  

Dataset wrap
Dataset2
RowSTUDYIDDOMAINUSUBJIDAESEQAELNKIDAETERMEPOCHAESTDTCAEENDTCAESTDYAEENDY
1TB005AE306711SKIN REDNESS
STUDY
PRODUCT
ADMINSISTRATION
EXPOSURE  2009-01-052009-01-071418

The RELREC dataset was used to record the relationship between the Product Events in PI and reported AE represented in AE dataset. 

...