Dataset wrap
Nametc
Rowcaps
Rows 1-9:Show the attributes of the testing regimen identified in PTTSTCND="E-Vapor Standard Aerosol Condition".  The value of this variable is taken directly from the value of PTTSTCND in the PT dataset from the stability study.
Rows 8-9:Show the puff pause duration and the puff pause interval. Taken together, these two records show that the regimen calls for a 60 second pause every 10 puffs.
Dataset2

Row

STUDYID

DOMAIN

PTTSTCND

TCSEQ

TCPARMCD

TCPARM

DIVAL

DIVALU

1

TOB07

TC

E-Vapor Standard Aerosol Condition

1

PUFFPROF

Puff Profile

SQUARE


2

TOB07

TC

E-Vapor Standard Aerosol Condition

2

PUFFDUR

Puff Duration 

1.25

sec

2

TOB07

TC

E-Vapor Standard Aerosol Condition

3

PUFFINT

Puff Interval

3

PUFF/min

4

TOB07

TC

E-Vapor Standard Aerosol Condition

4

PUFFBLCK

Puff Block

25

%

5

TOB07

TC

E-Vapor Standard Aerosol Condition

5

NUMPUFFTotal Number of Puffs

200

PUFF

6

TOB07

TC

E-Vapor Standard Aerosol Condition

6

PUFFVOLPuff Volume

10

mL

7

TOB07

TC

E-Vapor Standard Aerosol Condition

7

PUFFRNGPuff Range

100-200


8

TOB07

TC

E-Vapor Standard Aerosol Condition

8

PUFFPAUSPuff Pause

60

secs

9

TOB07

TC

E-Vapor Standard Aerosol Condition

9

PUFFPINTPuff Pause Interval

10

PUFF