The FAEX domain was used to represent the puff topography associated with the in-clinic visit.   A puff -by puff analysis was performed. FATPT was used to represent the time point, in this case, AM and PM.  Typically, the sponsor derives summary results using the individual source data records, these summary results are represented in ADaM.  However, if summary results are collected on a CRF or provided by an external vendor. these derived results can be represented in FAEX using the variable FACOLSRT. In this example, the sponsor created an ADaM dataset to represent the summary data ( Not Shown).      

Dataset wrap
Namefaex
Rowcaps
Rows 1, 6:Show the Number of Puff taken in the time interval specified in FADTC and FAENDTC.  This was pre-specified in the design, but the sponsor reported the actual number of puffs taken.  
Rows 2-5:Show the various measurements recorded for subject 3001 for Puff 1 during the morning administration of the tobacco product. FADTC and FAENDTC provides the timing of each puff.  The individual puff data for the afternoon are not shown. 
Rows 6-10:Show the various measurements recorded for subject 3001 for Puff 10 during the afternoon administration of the tobacco product. FADTC and FAENDTC provides the timing of each puff. The individual puff data for the morning session are not shown.  Note the data for PUFFS 2-9 are not shown to save space.  
Rows 12-15:  Show the various measurements recorded for subject 4001. Only a few rows are shown to save space.      
Dataset2
RowSTUDYIDDOMAINUSUBJIDSPDEVIDSPTOBIDFASEQFALNKIDFASPIDFATESTCDFATESTFAOBJFACATFAORRESFAORRESUFASTRESCFASTRESUFALOBXFLVISITNUMFADTCFAENDTCFATPT
1TGI400FA3001PUFANYXYZEC-33311
PUFF TOTTotal Number of Puffse-nicotine liquid

PUFF TOPOGRAPHY

10PUFFS10PUFFS22020-07-15T09:002020-07-15TT9:45

AM

2TGI400FA3001PUFANYXYZEC-33321PUFF 1PUFFVOLPuff Volumee-nicotine liquid

PUFF TOPOGRAPHY

36.7mL/sec37mL/sec2

2020-07-15T09:01.36

2020-07-15T09:01.38

AM

3

TGI400

FA3001PUFANYXYZEC-33331PUFF 1AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY15.5mL/sec15.5mL/sec22020-07-15T09:01.362020-07-15T09:01.38AM
4

TGI400

FA3001PUFANYXYZEC-33341PUFF 1PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY20.5mL/sec20.5mL/sec22020-07-15T09:01.362020-07-15T09:01.38AM
5

TGI400

FA3001PUFANYXYZEC-33351PUFF 1PUFFDURPuff Duratione-nicotine liquidPUFF TOPOGRAPHY2.0msec1.6msec22020-07-15T09:01.362020-07-15T09:01.38AM
6TGI400FA3001PUFANYXYZEC-33362
PUFF TOTTotal Number of Puffse-nicotin liquid

PUFF TOPOGRAPHY

9PUFFS9PUFFS22020-07-15T03:002020-07-15T03:30PM
7

TGI400

FA3001PUFANYXYZEC-33372PUFF 10INTPUFINPuff Intervale-nicotine liquidPUFF TOPOGRAPHY910396.8sec910396.8sec22020-07-15T03:30:342020-07-15T03:30:36PM
8

TGI400

FA3001PUFANYXYZEC-33382PUFF 10 10PUFFVOLPuff Volumee-nicotine liquidPUFF TOPOGRAPHY43mL/sec43mL/sec22020-07-15T03:30:342020-07-15T03:30:36

PM

9

TGI400

FA3001PUFANYXYZEC-33392PUFF 10AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY14.5mL/sec14.5mL/sec22020-07-15T03:30:342020-07-15T03:30:36

PM

10

TGI400

FA3001PUFANYXYZEC-333102PUFF 10PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY22.5mL/sec22.5mL/sec22020-07-15T03:30:342020-07-15T03:30:36

PM

12TGI400FA4001PUFANYXYZEC-33311
PUFF TOTTotal Number of Puffse-nicotine liquid

PUFF TOPOGRAPHY

10PUFFS10PUFFS22020-08-15T9:002020-08-15TT9:45

AM

13

TGI400

FA4001PUFANYXYZEC-33321PUFF 1PUFFVOLPuff Volumee-nicotine liquidPUFF TOPOGRAPHY34.7mL/sec34mL/sec22020-08-15T09:01.362020-08-15T09:01.38AM
14

TGI400

FA4001PUFANYXYZEC-33331PUFF 1AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY15.5mL/sec15.5mL/sec22020-08-15T09:01.362020-08-15T09:01.38AM
15

TGI400

FA4001PUFANYXYZEC-33341PUFF 1PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY23.5mL/sec23.5mL/sec22020-08-15T09:01.362020-08-15T09:01.38AM



...