Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Dataset wrap
Namefaex
Rowcaps
Rows 1, 6:Show the Number of Puff taken in the time interval specified in FADTC and FAENDTC.  This was pre-specified in the design, but the sponsor reported the actual number of puffs taken.  
Rows 2-5:Show the various measurements recorded for subject 3001 for Puff 1 during the morning administration of the tobacco product. FADTC and FAENDTC provides the timing of each puff.  The individual puff data for the afternoon are not shown. 
Rows 6-10:Show the various measurements recorded for subject 3001 for Puff 10 during the afternoon administration of the tobacco product. FADTC and FAENDTC provides the timing of each puff. The individual puff data for the morning session are not shown.  Note the data for PUFFS 2-9 are not shown to save space.  
Rows 12-15:  Shows the various measurements recorded for subject 4001. Only a few rows are shown to save space.      
Dataset2
RowSTUDYIDDOMAINUSUBJIDSPDEVIDFASEQFALNKIDFASPIDFATESTCDFATESTFAOBJFACATFAORRESFAORRESUFASTRESCFASTRESUFALOBXFLVISITNUMFADTCFAENDTCFATPT
1TGI400FA3001PUFANYXYZ11
PUFF TOTTOTAL NUMBER OF PUFFS e-nicotine liquid

PUFF TOPOGRAPHY

10PUFFS10PUFFS
22020-07-15T09:002020-07-15TT9:45

AM

2TGI400FA3001PUFANYXYZ21PUFF 1PUFFVOL PUFF VOLUMEe-nicotine liquid

PUFF TOPOGRAPHY

36.7mL/sec37mL/sec
2

2020-07-15T09:01.36

2020-07-15T09:01.38

AM

3

TGI400

FA3001PUFANYXYZ31PUFF 1AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY15.5mL/sec15.5mL/sec
22020-07-15T09:01.362020-07-15T09:01.38AM
4

TGI400

FA3001PUFANYXYZ41PUFF 1PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY20.5mL/sec20.5mL/sec
22020-07-15T09:01.362020-07-15T09:01.38AM
5

TGI400

FA3001PUFANYXYZ51PUFF 1PUFFDURPuff Duratione-nicotine liquidPUFF TOPOGRAPHY2.0msec1.6msec
22020-07-15T09:01.362020-07-15T09:01.38AM
6TGI400FA3001PUFANYXYZ62
PUFF TOTTOTAL NUMBER OF PUFFS e-nicotine liquid

PUFF TOPOGRAPHY

9PUFFS9PUFFS
22020-07-15T03:002020-07-15T03:30PM
7

TGI400

FA3001PUFANYXYZ72PUFF 10INTPUFINPuff Intervale-nicotine liquidPUFF TOPOGRAPHY910396.8sec910396.8sec
22020-07-15T03:30:342020-07-15T03:30:36PM
8

TGI400

FA3001PUFANYXYZ82PUFF 10 PUFFVOL PUFF VOLUME e-nicotine liquidPUFF TOPOGRAPHY43mL/sec43mL/sec
22020-07-15T03:30:342020-07-15T03:30:36

PM

9

TGI400

FA3001PUFANYXYZ92PUFF 10AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY14.5mL/sec14.5mL/sec

2020-07-15T03:30:342020-07-15T03:30:36

PM

10

TGI400

FA3001PUFANYXYZ102PUFF 10PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY22.5mL/sec22.5mL/sec

2020-07-15T03:30:342020-07-15T03:30:36

PM

12TGI400FA4001PUFANYXYZ11
PUFF TOTTOTAL NUMBER OF PUFFS e-nicotine liquid

PUFF TOPOGRAPHY

10PUFFS10PUFFS
22020-08-15T9:002020-08-15TT9:45

AM

13

TGI400

FA4001PUFANYXYZ21PUFF 1PUFFVOL PUFF VOLUMEe-nicotine liquidPUFF TOPOGRAPHY34.7mL/sec34mL/sec
22020-08-15T09:01.362020-08-15T09:01.38AM
14

TGI400

FA4001PUFANYXYZ31PUFF 1AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY15.5mL/sec15.5mL/sec
22020-08-15T09:01.362020-08-15T09:01.38AM
15

TGI400

FA4001PUFANYXYZ41PUFF 1PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY23.5mL/sec23.5mL/sec
22020-08-15T09:01.362020-08-15T09:01.38AM



The RELREC dataset was used to record the relationship between the Exposure records in EX and the records in FAEX.

...