Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

In this study, subjects were randomized to one of three 24-week conditions.  At the baseline visit, they receiving either an ENDS  device that used  0, 8 or 36 mg/ml nicotine liquid . Self-reported daily cigarette consumption were measured at all study visits  (Weeks 1, 2, 4, 8, 12, ). The subjects were supplied replacement nicotine cartridges. The sponsor used an electronic diary application to track when the cartridge were replaced, and the daily number of cigarettes smoked. The subject used their normal brand cigarettes, and these were not supplied by the sponsor. Each cartridge was 8 mL.  No other Nicotine replacement products were allowed to be used.  

The subject regular cigarettes were not supplied by the sponsor, and not considered a study product by the sponsor.  The sponsor reported the cigarettes used in the in the SU domain.  The SU domain is not shown here, but an example is shown in xxxxxx. 

Since the data in Exposure as collected would be practically identically to the summarized EX domain, the sponsor did not submit the EC domain.  A Product Accountability domain was submitted to represent dispensed and returned amounts, but this data was not used in determining exposure. It was used by the sponsor when reviewing the exposure data for each subject. This DA domain is not shown here.    

Note, the sponsor unblinded the study before creating the EX domain. The unblinded product name is provided in EXTRT, here a dummy name is used for the tobacco product.  

The domain represented the amount of product used, the total amount amount of liquid product ( including all is components) used from each cartridge and the associated nicotine pharmaceutical strength of each cartridge. The sponsored used this information in the analysis. The summaries included in the analysis  were the estimated number of cartridges used per week, and the estimated nicotine exposer from the cartridges per day.    

Since the data in Exposure as collected would be practically identically to the summarized EX domain, the sponsor did not submit the EC domain.  The DA domain was used to capture the amount of nicotine dispensed and returned for each cartridge. 

Note, the sponsor unblinded the study before creating the EX domain. The unblinded product name is used in EXTRT.  

Questions: 

Exposure collect may be be used to provided information on the amount of product used, or the amount of product used and the associated nicotine content. 

  1. Product used can be reflect in the number of the product used -number of cigarettes, number of patch, etc.   

      2.  Additionally, some sponsor may be interested in the amount of nicotine in the product itself. 

      3. The actual exposure to nicotine is typically analyzed using biomarkers,  measuring actual nicotine exposure from self-reported use can be challenging. 

The sponsor needs to decide what level of exposure information is needed for the particular study. 

EC was developed to allow the collection of exposure data as typically the actual exposure amount may be blinded. 

EX would at a minimal be provided. It is recognized that  EX is a derived domain. Some sponsor find it easier to report the collected data and the derived EX data to clearly provided exposure data with the tracking to what was collected.   In many cases, the derivation for EX, may just  be the unblinding of the product, and sponsor decide not to show the EC because the derivation used for EX is obvious.  Some  other details may be defined in an ADaM  dataset.  For example, the estimated daily nicotine exposure may based on self-reported may be provided. Since, thee are estimates, they are typically not reported in EX.     

We would like to develop some examples to try to  illustrated some common ways to provide this data that others can follow.             

We looked at ENDS- we collect amount of product used. We know the amount of e-liquid contained in the product when pre-filled containers are used. We also know the concentration of nicotine in the e-liquid. The study analysis plan decide what is of interest in the study     

We looked at SDTM and would like to discuss options for representing  this information. First , we looked at the derived EX dataset.  

EX would report the unblinded exposure to e-nicotine liquid. 

1) The dose may be the actual volume of liquid used over the interval represented in the dates, or that x containers were used, or weight of the container etc.   

This  EX dataset attempts to provide all the basic information.   

...

Use container such as a cartridge or tank.  Hence used CT of container  to be generic. 

DOSEU  - QUID is not included in CT. 

Dataset wrap
NameEX
Dataset2
RowSTUDYIDDOMAINUSUBJIDEXSEQEXREFEXTRTEXDOSEEXDOSUEXROUTE
ECVAMT
EXVAMTEXVAMTU
EXPSTRGEXPSTRGEXSTDTCEXENDTC
1TENDS01EX10001 1
e-nicotine liquid
CRT8754Tobacco  X1 Nicotine Cartridge1CONTAINERINHALED6mL8mg/mL2020-06-272020-07-01
2TENDS01EC10001 2
e-nicotine liquid 
CRT9754Tobacco  X1 Nicotine Cartridge1CONTAINERINHALED6.7mL8mg/mL2020-07-012020-07-05
3TENDS01EC10001 3
e-nicotine liquid  
CRT9756Tobacco  X1 Nicotine Cartridge1CONTAINERINHALED8mL8mg/mL2020-07-052020-07-10
4TENDS01EC100021
e-nicotine liquid  
CRT8000Tobacco  X2 Nicotine Cartridge1CONTAINERINHALED5mL36mg/mL2020-09-012020-09-07
5TENDS01EC10002 2
CRT9006Tobacco  X2 Nicotine Cartridge
e-nicotine liquid 
1CONTAINERINHALED7mL36mg/mL2020-09-072020-09-14
6TENDS01EC10002 3
e-nicotine liquid 
CRT9008Tobacco  X2 Nicotine Cartridge1CONTAINERINHALED8mL36mg/mL2020-09-142020-09-21
7TENDS01EC10002 4
CRT901Tobacco  X2 Nicotine Cartridge
e-nicotine liquid 
1CONTAINERINHALED6mL36mg/mL2020-09-212020-09-28
8TENDS01EC10002 5
e-nicotine liquid 
CRT908Tobacco  X2 Nicotine Cartridge1CONTAINERINHALED7mL36mg/mL2020-09-282020-09-31
9TENDS01EC10002 6
e-nicotine liquid 

Tobacco  X2 Nicotine Cartridge1CONTAINERINHALED8mL36mg/mL2020-10-312020-10-08
10TENDS01EC10002 7
e-nicotine liquid 

Tobacco  X2 Nicotine Cartridge1CONTAINERINHALED6.7mL36mg/mL2020-10-082020-10-15
11TENDS01EC10002 8
e-nicotine liquid 

Tobacco  X2 Nicotine Cartridge1CONTAINERINHALED5.5mL36mg/mL2020-10-152020-10-22

Various options exist . This example however, exclude the amount of product used. This could be shown in EC.   

In this case, i get the volume used from DA and derive this. 

RowSTUDYIDDOMAINUSUBJIDEXSEQEXTRTEXDOSEEXDOSUEXROUTEEXPSTRGEXPSTRGEXSTDTCEXENDTC
1TENDS01EX10001 1e-nicotine liquid7mLINHALED8mg/mL2020-06-272020-07-01
2TENDS01EC10001 2e-nicotine liquid 6mL INHALED8mg/mL2020-07-012020-07-05
3TENDS01EC10001 3e-nicotine liquid  7mL INHALED8mg/mL2020-07-052020-07-10
4TENDS01EC100021e-nicotine liquid  6mL INHALED36mg/mL2020-09-012020-09-07
5TENDS01EC10002 2e-nicotine liquid 5mL INHALED36mg/mL2020-09-072020-09-14
6TENDS01EC10002 3e-nicotine liquid 8mL INHALED36mg/mL2020-09-142020-09-21
7TENDS01EC10002 4e-nicotine liquid 8mL INHALED36mg/mL2020-09-212020-09-28
8TENDS01EC10002 5e-nicotine liquid 8mL INHALED36mg/mL2020-09-282020-09-31
9TENDS01EC10002 6e-nicotine liquid 8mL INHALED36mg/mL2020-10-312020-10-08
10TENDS01EC10002 7e-nicotine liquid 7mL INHALED36mg/mL2020-10-082020-10-15
11TENDS01EC10002 8e-nicotine liquid 7mL INHALED36mg/mL2020-10-152020-10-22
Panel
CANCan Dosing UnitA dosing measurement based on the can unit.(NCI)Can Dosing Unit
CONTAINERContainer Dosing UnitA dosing measurement based on the container unit.(NCI)Container Dosing Unit
CIGARCigar Dosing UnitA dosing measurement based on the cigar unit.
CIGARETTECigarette Dosing UnitA dosing measurement based on the cigarette unit.
PUFFPuff Dosing UnitA means of delivering a defined dose of a therapeutic aerolized solution into either the upper or lower respiratory tract. Metered-dose inhalers or spray pumps are devices that provide a puff dose for delivery into either the oral or the nasal cavity.(NCI)
CARTRIDGECartridge Dosing UnitA dosing measurement based on the cartridge unit.(NCI)

More unit codes as well- PACK, PACKAGE, CIGAR, Cigarettes. POUCH,  

  1. When the EC domain is implemented in conjunction with the EX domain, EXVAMT and EXVAMTU would not be used in EX; collected values instead would be represented in ECDOSE and ECDOSU (and ECVAMT and ECVAMTU as needed).

     

Use container such as a cartridge or tank.  Hence used CT of container  to be generic. 

DOSEU  - QUID is not included in CT. 

...

CONTAINERContainer Dosing UnitA dosing measurement based on the container unit.(NCI)Container Dosing Unit
CIGARCigar Dosing UnitA dosing measurement based on the cigar unit.
CIGARETTECigarette Dosing UnitA dosing measurement based on the cigarette unit.
PUFFPuff Dosing UnitA means of delivering a defined dose of a therapeutic aerolized solution into either the upper or lower respiratory tract. Metered-dose inhalers or spray pumps are devices that provide a puff dose for delivery into either the oral or the nasal cavity.(NCI)
CARTRIDGECartridge Dosing UnitA dosing measurement based on the cartridge unit.(NCI)

More unit codes as well- PACK, PACKAGE, CIGAR, Cigarettes. POUCH,  



The  DA domain contained the amount dispensed and returned for each cartridge.  Each cartiridge had a unique number assigned. This  was represented in DAREF.    

Dataset wrap

 In this study, subjects were randomized to one of three 24-week conditions.  At the baseline visit, they receiving either an ENDS  device that used  0, 8 or 36 mg/ml nicotine liquid . Self-reported daily cigarette consumption  were measured at all study visits  (Weeks 1, 2, 4, 8, 12, ). The subjects were supplied replacement nicotine cartridges.  The sponsor used an electronic diary application to track when the cartridge were replaced, and the daily number of cigarettes smoked.  The subject used their normal brand cigarettes , and these were not supplied by the sponsor. Each cartridge was 8 mL.  

Vapes, vaporizers, vape pens, hookah pens, electronic cigarettes (e-cigarettes or e-cigs), e-cigars, and e-pipes are some of the many tobacco product terms used to describe electronic nicotine delivery systems (ENDS). These products use an “e-liquid” that usually contains nicotine derived from tobacco, as well as flavorings, propylene glycol, vegetable glycerin, and other ingredients. The liquid is heated to create an aerosol that the user inhales.

Since, the subject regular cigarettes were not supplied by the sponsor, the sponsor elected to report this data as a Concomitant medication, in the CM domain. The ENDS device exposure use was represented in EC.        

 

Dataset wrap
NameEC
Dataset2
RowSTUDYIDDOMAINUSUBJID
ECSEQ
DASEQ
ECTRT
DAREF
ECDOSE
DATESTCD
ECDOSU
DATEST
ECROUTE
DACAT
ECVAMT
DAORRES
ECVAMT
DAORRESU
ECSTDTC
DASTRESC
ECENDTC
DASTRESN
1
DASTRESU
TENDS01
VISITNUM
EC
DADTC
10001 
1
e-nicotine liquid 1CONTAINERINHALED8mL2020-06-272020-07-01
2TENDS01EC10001 2

e-nicotine liquid 

1CONTAINERINHALED8mL2020-07-012020-07-05
3TENDS01EC10001 3e-nicotine liquid  1CONTAINERINHALED8mL2020-07-052020-07-10
4TENDS01EC100021e-nicotine liquid 1CONTAINERINHALED8mL2020-09-012020-09-07
5TENDS01EC10002 2e-nicotine liquid 1CONTAINERINHALED8mL2020-09-072020-09-14
6TENDS01EC10002 3e-nicotine liquid 1CONTAINERINHALED8mL2020-09-142020-09-21
7TENDS01EC10002 4e-nicotine liquid 1CONTAINERINHALED8mL2020-09-212020-09-28
8TENDS01EC10002 5e-nicotine liquid 1CONTAINERINHALED8mL2020-09-282020-09-31
9TENDS01EC10002 6e-nicotine liquid 1CONTAINERINHALED8mL2020-10-312020-10-08
10TENDS01EC10002 7e-nicotine liquid 1CONTAINERINHALED8mL2020-10-082020-10-15
11TENDS01EC10002 8e-nicotine liquid 1CONTAINERINHALED8mL2020-10-152020-10-22

EX would report the unblinded exposure to e-nicotine liquid. 

1) The dose may be the actual volume of liquid used over the interval represented in the dates, or that 1 container was used, or xxx. 

2. IF amount of product used ( Numer of pouches, number of cigarettes, etc then we may be able to use VAMT, and Pharmaceutical strength to provide more details. 

...

ABCDAABC-01001

1

CRT8754DISPAMTDispensed AmountSTUDY PRODUCT28.5g28.528.5mL12004-06-15
2ABCDAABC-01001

2

CRT8754RETAMTReturned AmountSTUDY PRODUCT0.5g0.50.5mL22004-06-29
3ABCDAABC-01001

3

CRT9754DISPAMTDispensed AmountSTUDY PRODUCT28.8g28.828.8mL22004-06-29
4ABCDAABC-01001

4

CRT9754RETAMTReturned AmountSTUDY PRODUCT0.75g0.750.75mL32004-07-15