Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Dataset wrap
Namett



Dataset2
RowSTUDYIDDOMAINSPTOBIDTTSEQTTTESTCDTTTESTTTORRESTTORRESUTTSTRESCTTSTRESNTTSTRESU
1TOB07DPCIG01a

1

LENGTHLength
mm

mm
2TOB07DPCIG01a2CIRCUMFCircumference
mm

mm
3TOB07DPCIG01a3TBFLMASSTobacco Filler Mass
mg

mg
4TOB07DPCIG01a4MOISTUREMoisture
%

%
5TOB07DPCIG01a5TOCUTSIZTobacco Cut Size
mm or cuts per inch 2

mm or cuts per inch 2
6TOB07DPCIG01a6FLTRVENTFilter Ventilation
%

%
7TOB07DPCIG01a7TPNPLGTHTipping Paper Length
mm

mm
8TOB07DPCIG01a8CIGBPPORCigarette Base Paper Porosity or Permeability
CORESTA Unit (Cu)

CORESTA Unit (Cu)
9TOB07DPCIG01a9BNDDIFCigarette Paper Band Porosity or Permeability or Band Diffusivity
CORESTA Unit (Cu) or cm2/s

CORESTA Unit (Cu) or cm2/s
10TOB07DPCIG01a10CPBNDWIDCigarette Paper Band Width
mm

mm
11TOB07DPCIG01a11CPBNDSPCCigarette Paper Band Space
mm

mm
12TOB07DPCIG01a12FLTREFFFilter Efficiency
%

%
13TOB07DPCIG01a13DPFDenier Per Filament
/filament

/filament
14TOB07DPCIG01a14DENIERDenier
g/9000 m

g/9000 m
15TOB07DPCIG01a15FLTRDENFilter Density
g/cm3

g/cm3
16TOB07DPCIG01a16FLTRLGTHFilter Length
mm

mm
17TOB07DPCIG01a17FLTPRDRPFilter Pressure Drop
mm H2O

mm H2O
18TOB07DPCIG01a18TORODDENTobacco Rod Density
g/cm3

g/cm3
19TOB07DPCIG01a19CIGPLGTHCigarette Paper Length
mm

mm


The following tables illustrate the controlled terminology for the the --TESTCD and --TEST values that should be submitted in datasets according to the examples above. (We'll add more language as necessary to make this clearer)

Expand
titleWaterpipe Tobacco Products
Expand
titleWaterpipe Tobacco Product Identifiers and Descriptors
TOTESTCDTOTESTTOSTRESC*Description
TBPRDCATTobacco Product CategoryWaterpipe Tobacco Product
TBPRSCATTobacco Product Subcategoryx;y;z
MANUFManufacturer--TOSTRESC not subject to controlled terminology for this TEST/TESTCD. Use verbatim name
TRADENAMTrade Name--TOSTRESC not subject to controlled terminology for this TEST/TESTCD. Use verbatim name




















*Where TOSTRESC is subject to controlled terminology, use the value (or one of the values) shown in this column.



Since the conformance testing of the design parameters and the design parameters themselves speak to the same concepts, they use the same terminology

Expand
titleWaterpipe Tobacco Product Design Parameters and Conformance Testing
DPTESTCD /TTESTCDDPTEST/TTTESTDescription




























This images shows the filtration zone where the ventilation occurs.

...