Excerpt Include |
---|
| TAA and AAA concept map 2 |
---|
| TAA and AAA concept map 2 |
---|
|
Case 1 - Subject has both TAA and AAA
The subject had CT scans performed on the chest and abdomen.
...
Dataset wrap |
---|
|
Rowcaps |
---|
Row 1: | I examined the image of the thoracic region (test location) and found an aneurysm in the Thoracic Aorta (result location) spanning from the aortic arch to the descending aorta (result location detail). In this case result location detail further qualifies both ORRES and RESLOC, hence this is a variable qualifier. |
---|
Row 2: | I measured the diameter of the aneurysm from aortic arch to the descending aorta (test location). |
---|
Row 3: | I examined the image of the thoracic region (test location) and found that the descending aorta (result location) had severely dissected (the artery is tore and a false lumen had formed), most likely due to the enormous pressure caused by the large aneurysm in this area. |
---|
Row 4: | The dissected descending aorta (test location) is classified based on the Stanford Aortic Dissection System as type B. |
---|
Row 5: | I examined the image of the abdominal region (test location) and found an aneurysm in the infrarenal aorta (result location), proximal to the iliac bifurcation (result location detail). In this case result location detail is a variable qualifier for the result, I am trying to say that the aneurysm is located in the segment of the infrarenal aorta closer (proximal) to the iliac bifurcation. |
---|
Row 6: | I measured the diameter of the infrarenal aortic (test location) aneurysm. |
---|
Row 7: | I examined the image of the abdominal region and found that the infrarenal aorta (result location) had dissected. |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | CVSEQ | CVGRPID | CVTEST | CVORRES | CVORRESU | CVLOC | CVLOCDTL | CVMETHOD | VISITNUM | VISIT | CVDTC |
| CVRESLOC
| CVRESLOC Detail |
---|
1 | ABC | CV | ABC-123 | 1 | 1 | Aneurysm Indicator | Y |
| Thoracic region |
| CT SCAN | 1 | BASELINE | 2020-04-27 |
| Thoracic Aorta | Aortic Arch to Descending aorta |
---|
2 | ABC | CV | ABC-123 | 2 | 1 | Aneurysm Diameter | 6 | cm | Thoracic Aorta | Aortic Arch to Descending aorta | CT SCAN | 1 | BASELINE | 2020-04-27 |
|
|
|
---|
3 | ABC | CV | ABC-123 | 3 | 2 | Dissection Indicator | Y |
| Thoracic region |
| CT SCAN | 1 | BASELINE | 2020-04-27 |
| Descending aorta |
|
---|
4 | ABC | CV | ABC-123 | 4 | 2 | Stanford AoD Classification | Stanford B |
| Descending aorta |
| CT SCAN | 1 | BASELINE | 2020-04-27 |
|
|
|
---|
5 | ABC | CV | ABC-123 | 5 | 3 | Aneurysm Indicator | Y |
| Abdominal region |
| CT SCAN | 1 | BASELINE | 2020-04-27 |
| Infrarenal aorta | proximal to the iliac bifurcation |
---|
6 | ABC | CV | ABC-123 | 6 | 3 | Aneurysm Diameter | 7 | cm | Infrarenal aorta | proximal to the iliac bifurcation | CT SCAN | 1 | BASELINE | 2020-04-27 |
|
|
|
---|
7 | ABC | CV | ABC-123 | 7 |
| Dissection Indicator | Y |
| Abdominal region |
| CT SCAN | 1 | BASELINE | 2020-04-27 |
| Infrarenal aorta | proximal to the iliac bifurcation |
---|
|
|
Case 2 - Subject has AAA but TAA is not found
The subject had a MRI performed on the torso (trunk).
...