Dataset wrap
titlelb.xpt
Namemb


Rowcaps


Rows 1-2:Show the screening, followed by confirmatory detection of Influenza A virus RNA in a nasal specimen by Rapid PCR test.
Row 3:Shows viral load of the previously detected Influenza A virus RNA.



Dataset2


RowSTUDYIDDOMAINUSUBJIDMBSEQMBGRPIDMBTESTCDMBTESTMBTSTDTLMBTSTOPOMBCATMBORRESMBORRESUMBSTRESCMBSTRESNMBSTRESUMBSPECMBLOCMBMETHODVISITNUMVISITMBDTC
1ABCMBABC-00111INFARNAInfluenza A RNADETECTIONSCREENMICROBIOLOGYYES
YESYES
MUCUSNOSTRIL

RAPID PCR

1SCREEN2018-06-01
2ABCMBABC-00131INFARNAInfluenza A RNADETECTIONCONFIRMMICROBIOLOGYYES
YESYES

log 10 IU/mL

MUCUSNOSTRIL

RAPID PCR

1SCREEN2018-06-01
3ABCMBABC-00112INFARNAInfluenza A RNA

VIRAL LOAD

QUANTIFYMICROBIOLOGY4.5log 10 copies/mL4.54.5log 10 copies/mLMUCUSNOSTRIL

QUANTITATIVE REVERSE TRANSCRIPTASE POLYMERASE CHAIN REACTION

1SCREEN2018-06-01



Option 1 - for the quantification 2nd step, use --TSTOPO since we already proposed controlled terminology

Note: if I remember correctly we specifically avoided the term "quantification" because the test can be "semi, pseudo, or fully quantitative", we found this term just toooo vague.

Dataset wrap
titlelb.xpt
Namemb



Dataset2


RowSTUDYIDDOMAINUSUBJIDISSEQISGRPIDISTESTCDISTESTISBDAGNTISTSTOPOISCATISORRESISORRESUISSTRESCISSTRESNISSTRESUISMETHODVISITNUMVISITMBDTC
1ABCMBABC-00111
Anti-microbial IgM AntibodySARS-CoV-2SCREENMICROBIOLOGYYES
YESYES
EIA1SCREEN2018-06-01
2ABCMBABC-00131
Anti-microbial IgM AntibodySARS-CoV-2QUANTIFYMICROBIOLOGY350Titer350350

Titer